Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
1.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1523860

ABSTRACT

Objective: The aim of this in vitro study w as t o analyze the influence of the titanium dioxide nanotubes i n a self-cure mode polymerization of a dual resin luting agent through push out bond strength and radiopacity tests. Material and Methods: After mixed with a commercial du al self-adhesive resin cement, three concentrations o f tit anium dioxide nanotubes (0.3, 0.6, and 0.9% by weight) we re analyzed in self-curing mode. T he bond strength to bovine root dentin and fi berglass posts was assessed with the push out bond str ength t est and was evaluated in three thirds (cervical, middle and apical) (n=10), followed by failure mode analysis (SEM), and the ISO standard 9917-2 was followed for radiopacity test (n=10). Data were statistically analyzed by one-way ANOVA test, followed by Tukey's test (α=0.05). Results: Reinforced self-adhesive resin cement with 0.6% titanium dioxide nanotubes showed significant difference compared to the control gr oup for push out test (p=0.00158). The modified groups did not s how significant difference among thirds (p=0.782). Radiopacity sh owed higher value for group w ith 0.9% titanium dioxide nanotubes in comparison w ith control group (p<0.001). Conclusion: The addition of titanium dioxide nanotubes to a self-adhesive resin cement increased the bond strength to dentin and radiopacity values in the self-cure polymerization mode (AU)


Objetivo: O objetivo deste estudo in vitro foi analisar a influência de nanotubos de dióxido de titânio na polimerização química de um agente cimentante resinoso dual através de testes de resistência à união e radiopacidade. Material e Métodos: Após misturado com um cimento resinoso auto-adesivo comercial, três concentrações de nanotubos de dióxido de titânio (0,3, 0,6 e 0,9% em peso) foram analisadas. A resistência da união para a dentina da raiz bovina e os pinos de fibra de vidro foi avaliada pelo teste de push-out e avaliada em três terços (cervical, médio e apical) (n = 10), seguido pelo análise de modo de falha (MEV) e a norma ISO 9917-2 foi seguido para teste de radiopacidade (n = 10). Os dados foram analisados estatisticamente pelo teste ANOVA um fator seguido do teste de Tukey (α = 0,05). Resultados: O cimento resinoso auto-adesivo reforçado com nanotubos de dióxido de titânio a 0,6% mostrou diferença significativa em comparação com o grupo controle para teste de push-out (p=0,00158). Os grupos modificados não mostraram diferença significativa entre os terços (p=0,782). A radiopacidade mostrou maior valor para o grupo com nanotubos de dióxido de titânio 0,9% em comparação com o grupo controle (p<0,001). Conclusão: A adição de nanotubos de dióxido de titânio a um cimento resinoso auto-adesivo aumentou a os valores de resistência de união à dentina e radiopacidade no modo de polimerização química do agente cimentante (AU)


Subject(s)
Titanium , Dental Cements , Dental Pins , Nanotubes
2.
São José dos Campos; s.n; 2022. 78 p. tab, ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1397436

ABSTRACT

Este estudo, desenvolvido em duas etapas, avaliou a ação remineralizadora da biopartícula α-wollastonita (BP), a partir da reação com H3PO4 residual Si-O-Ca + H3PO4 → SiO2 + Ca5(PO4)3(OH)n + H2O, na resistência longitudinal de união e características da interface adesiva, quando aplicada na forma de suspensão (etanol 99,5% + 10% de BP em peso) na superfície dentinária previamente condicionada com H3PO4 37%. Na primeira etapa foi realizado um estudo piloto onde, pelas características de precipitação, foi identificada a melhor concentração de biopartículas a serem inseridas na formulação da suspensão. Na segunda etapa, duzentas coroas hígidas de incisivos bovinos foram embutidas em resina acrílica, polidas para padronizar a smear layer e divididas aleatoriamente em 2 grupos (n=100), segundo a estratégia adesiva: A - controle (H3PO4 + Single Bond™ Universal (SB)); WAS ­ (H3PO4 + BP em suspensão + SB). Blocos de resina composta (Filtek Z250; 3M/ESPE) de 4mm foram confeccionados por técnica incremental sobre as áreas tratadas em todos os grupos, utilizando uma matriz de silicona. As amostras foram então seccionadas para obtenção de palitos retangulares (aproximadamente 1mm2 ), armazenadas em água deionizada a 4ºC em recipientes individuais e divididas em 2 subgrupos (n=50) de acordo com o tempo de armazenamento de 24 h (imediato) e 12 meses (longitudinal), seguidos do teste de resistência adesiva à microtração (10 kgf, 0,5mm/min). Os dados foram submetidos ao teste ANOVA 2 fatores (p< 0,05) e teste de Weibull 2 parâmetros. As interfaces adesivas foram analisadas por microscopia eletrônica de varredura (MEV) para avaliar a morfologia da interface resina-dentina, e analisadas por espectroscopia FTIR, para compreensão das interações químicas formadas na superfície dentinária. Os Resultados evidenciaram maiores valores estatisticamente significativos de resistência de união (MPa) para o grupo WAS (37,39 ± 7,48), tratado com BP e armazenado por 24 h, em comparação ao grupo A armazenado por 24 h (27,58 ± 6,43); e, para o grupo WAS armazenado por 12 meses (32,05 ± 10,64) em comparação ao grupo A armazenado por 12 meses (22,84 ± 5,76). Dados do FTIR evidenciaram o efeito da α-wollastonita na preservação do colágeno. A biopartícula mostrou ser promissora na manutenção longitudinal da qualidade da interface adesiva. (AU)


This study, developed in two stages, evaluated the remineralizing action of the αwollastonite (BP) bioparticle, from the reaction with residual Si-O-Ca + H3PO4 → SiO2 + Ca5(PO4)3(OH)n + H2O, on the longitudinal bond strength and characteristics of the adhesive interface, when applied as a suspension (99.5% ethanol + 10% BP by weight) on the dentin surface previously etched with 37% H3PO4. In the first stage, a pilot study was carried out where, due to the precipitation characteristics, the best concentration of bioparticles to be inserted in the suspension formulation was identified. In the second step, two hundred sound bovine incisor crowns were embedded in acrylic resin, polished to standardize the smear layer and randomly divided into 2 groups (n=100), according to the adhesive strategy: A - control (H3PO4 + Single Bond™ Universal (SB)); WAS ­ (H3PO4 + BP in suspension + SB). Composite resin blocks (Filtek Z250; 3M/ESPE) of 4 mm were made by incremental technique on the treated areas in all groups, using a silicone matrix. The samples were then sectioned to obtain rectangular sticks (approximately 1mm2 ), stored in deionized water at 4ºC in individual containers and divided into 2 subgroups (n=50) according to the storage time of 24 h (immediate) and 12 months (longitudinal), followed by the microtensile bond strength test (10 kgf, 0.5 mm/min). Data were submitted to 2-way ANOVA (p<0.05) and 2-parameter Weibull test. The adhesive interfaces were analyzed by scanning electron microscopy (SEM) to evaluate the morphology of the resin-dentin interface, and analyzed by FTIR spectroscopy, to understand the chemical interactions formed on the dentin surface. The results showed higher statistically significant values of bond strength (MPa) for the WAS group (37.39 ± 7.48), treated with BP and stored for 24 h, compared to group A stored for 24 h (27, 58 ± 6.43); and for the WAS group stored for 12 months (32.05 ± 10.64) compared to group A stored for 12 months (22.84 ± 5.76). FTIR data evidenced the effect of α-wollastonite on collagen preservation. The bioparticle showed promise in the longitudinal maintenance of the quality of the adhesive interface (AU)


Subject(s)
Animals , Cattle , Acrylic Resins , Analysis of Variance , Composite Resins , Dental Cements , In Vitro Techniques , Microscopy, Electron, Scanning , Collagen
3.
Braz. dent. sci ; 24(1): 1-6, 2021. tab
Article in English | BBO, LILACS | ID: biblio-1145511

ABSTRACT

Objective: The present study aimed to assess theinfluence of vibration effect on microshear bond strength (µSBS) of flowable composite to enamel. Material and Methods: Sixty non-cariousextracted human premolar teeth were collected and randomly divided into six groups (n = 10) after being trimmed to produce a smooth flat surface: Flowable composites [Wave (SDI), Wave HV (SDI) and Grandioflow (Voco)] were used as bonding agents without or with vibration using an ultrasonic scaler (Mini Piezon, EMS, Switzerland). Composite resin, with an internal diameter of 0.7mm and height of 1mm, was cured on the substrate. The specimens' µSBS was tested by a microtensile tester (Bisco, USA) at a crosshead speed of 0.5 mm/min. The bond strength values were analyzed using one-way ANOVA and post hoc Tukey test (p < 0.05). Results:Vibrationdid not lead to any significant difference in the µSBS values of Wave, Wave HV, and Grandio Flow µSBS values (P=0.690, P=1.000 and P=0.947, respectively). No significant difference was found between flowable composites in terms of micro shear bond strength to enamel (p > 0.05). Conclusions: The application of ultrasonicvibration might not be advantageous in terms of improving the shear bond strength of flowable composites to enamel. (AU)


Objetivo: Este estudo teve como objetivo avaliar a influência de microcisalhamento com efeito de vibração na resistência de união (µSBS) de compósito fluido ao esmalte. Material e Métodos: Sessenta dentes pré-molares humanos extraídos não cariados foram coletados e divididos aleatoriamente em seis grupos (n = 10) após serem desgastados para produzir uma superfície lisa e plana: Compósitos fluidos [Wave (SDI), Wave HV (SDI) e Grandioflow (Voco)] foram usados como agentes adesivos sem e com vibração através de um aparelho ultrassônico (Mini Piezon, EMS, Switzerland). Uma resina composta, com diâmetro interno de 0,7 mm e peso de 1 mm, foi polimerizada no substrato. Os espécimes de µSBS foram submetidos a teste de microtração (Bisco, USA) em uma velocidade de 0.5 mm/min. Os valores de resistência adesiva foram analisados através de testes de ANOVA a um critério e de Tukey post hoc (p < 0.05). Resultados: A vibração não levou a nenhuma diferença significativa nos valores de µSBS entre Wave, Wave HV, e Grandio Flow (P=0.690, P=1.000 e P=0.947, respectivamente). Não foi encontrada nenhuma diferença significativa entre os compósitos fluidos quanto à resistência de união ao esmalte quando sob microcisalhamento (p >0.05). Conclusões: A aplicação de vibração ultrassônica pode não ser vantajosa para uma melhora na resistência adesiva de compósitos fluidos ao esmalte frente a cisalhamento. (AU)


Subject(s)
Humans , Vibration , Bicuspid , Composite Resins , Dental Enamel
4.
Braz. dent. sci ; 23(1): 1-7, 2020. tab
Article in English | LILACS, BBO | ID: biblio-1049603

ABSTRACT

Objective: Evaluate the microtensile bond strength (µTBS) in different dentin thicknesses, under simulated pulpal pressure (SPP), submitted to an adhesive technique using laser irradiation. Material and methods: Forty sound human molars were sectioned and randomly divided into two groups (n=20): Group 1 ­ 1 mm of dentin thickness; Group 2 ­ 2 mm of dentin thickness. Each group was divided into two subgroups (n=10): Subgroup A ­ Absence of SPP; Subgroup P ­ Presence of SPP (15 cm H2 O). The samples were sequentially treated with: 37% phosphoric acid, adhesive system (Adper Single Bond 2), Nd:YAG laser irradiation (60 s, 1064 nm, 10 Hz) using 60 and 100 mJ/pulse energy parameters and photopolymerization (10 s). A composite resin block (Filtek Z350) was built up onto the irradiated area. After 30 days stored in water, the samples were sectioned and submitted to microtensile test (10 kgf load cell, 0.5mm/min). Data were analyzed by twoway ANOVA and Tukey tests. Results: Two-way ANOVA revealed no significant differences for SPP on bond strength. The laser energy parameters indicated that 100 mJ showed greater µTBS means compared to the group irradiated with 60 mJ. The presence of SPP reduced the mean µTBS values. Conclusions: Simulated pulpal pressure did not affect the µTBS using 60 mJ of laser energy parameter. At 100 mJ, the presence of SPP negatively influenced the bond strength, regardless of dentin thickness (AU)


Objetivo: O objetivo deste estudo foi avaliar a resistência adesiva (RA) em diferentes espessuras de dentina, associada à pressão pulpar simulada (PPS), quando submetidos à técnica adesiva por irradiação laser. Material e Métodos: Quarenta molares humanos hígidos foram seccionados e divididos aleatoriamente em dois grupos (n=20): Grupo 1 ­ 1 mm de espessura de dentina; Grupo 2 ­ 2 mm de espessura de dentina. As amostras foram divididas em 2 subgrupos (n=10): Subgrupo A ­ ausência de PPS; Subgrupo P ­ presença de PPS (15 cm de H2 O). As amostras foram tratadas seqüencialmente com: ácido fosfórico 37%, sistema adesivo (Adper Single Bond 2), irradiação com Nd:YAG laser (60 s, 1064 nm, 10 Hz) nos parâmetros de energia de 60 e 100 mJ/pulso e fotopolimerização (10 s). Um bloco de resina composta (Filtek Z350, 3M ESPE) foi confeccionado sobre a área irradiada. Após 30 dias armazenados em água, os espécimes foram seccionados e submetidos ao teste de microtração (carga de 10 kgf, 0.5mm/min). Os dados foram analisados pelos testes ANOVA sob 2 fatores e Tukey (p<0.05). Resultados: ANOVA mostrou que não houve diferenças significativas para PPS na RA. Para os parâmetros de energia do laser, 100 mJ apresentou maiores médias de RA quando comparado ao grupo irradiado à 60 mJ. A presença da PPS reduziu as médias de RA. Conclusão: Pressão pulpar simulada não afetou os valores de resistência adesiva para o grupo irradiado com 60 mJ. Para 100 mJ, a presença da pressão pulpar influenciou negativamente na resistência adesiva, independente das espessuras de dentina.(AU)


Subject(s)
Humans , Dental Cements , Dental Pulp , Dentin , Lasers, Solid-State , Hydrostatic Pressure , Random Allocation , Analysis of Variance , Composite Resins , Dentin/radiation effects , Molar
5.
Rev. odontol. UNESP (Online) ; 49: e20200020, 2020. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1139417

ABSTRACT

Introduction: The silanization of the ceramic surface prior to applying the adhesive and/or resinous materials plays an important role in bond strength. Nowadays, a new family of adhesive systems has been introduced into the market, aiming to simplify the technique of adhesive procedures during cementation. Objective: To investigate the effectiveness of different bonding agents containing silane and primer on Lithium Disilicate Glass Ceramic (LD) surface by shear bond strength tests. Material and method: 130 LD ceramic blocks were included in acrylic resin, polished and washed in ultrasound for 10 minutes. The specimens were divided into 2 groups according to surface treatment: Polished Surface (PS); Hydrofluoric Acid 9.5% - 20s (HF). Each group was divided into 5 subgroups (n = 13) according to bonding agent type: metallic primer containing MDP (ZPrimePlus, Bisco Inc); two traditional silanes (MonobondPlus, IvoclarVivadent / Porcelain Prime, Bisco Inc.); mixture of silane and resin (Kerr Silane, Kerr); mixture of silane and universal adhesive (Single-bond Universal, 3M Espe). The specimens were mounted in a standard device for shear testing (UltradentBonding Assembly), cemented with dual resin cement (RelyX UltimateTM, 3M Espe.) and photo-polymerized for 20s. The samples were tested after 24 hours and 3 months of storage in distilled water at ±36 °C. The data were analyzed by 3-Way Anova and Tukey's test (α = 5%). Result: Shear bond strength (SBS) was significantly influenced by surface treatment, bonding agent used and storage (p <0.001). Conclusion: Adequate adhesive bond strength to Lithium Disilicate Glass Ceramic can be obtained with traditional silanes, combined with HF acid pretreatment surface.


Introdução: A silanização da superfície cerâmica antes da aplicação do adesivo e/ou materiais resinosos desempenha um papel importante na resistência adesiva. Atualmente, uma nova família de sistemas adesivos foi introduzida no mercado, visando simplificar a técnica dos procedimentos adesivos durante a cimentação. Objetivo: Investigar a eficácia de diferentes soluções contendo silano e primer na superfície de cerâmicas de Dissilicato de Lítio (DLT) por meio de testes de resistência adesiva por cisalhamento. Material e método: 130 blocos cerâmicos DLT foram incluídos em resina acrílica, polidos e lavados em ultra-som por 10 minutos. Os espécimes foram divididos em 2 grupos de acordo com tratamento de superfície: Superfície Polida (PS); Ácido Hidro-Fluorídrico 9,5% - 20s (HF). Cada grupo foi dividido em 5 sub-grupos (n = 13) de acordo com o tipo de primer/silano: primer metálico contendo MDP (ZprimePlus, Bisco Inc); dois silanos tradicionais (MonobondPlus, IvoclarVivadent / Porcelain Prime, Bisco Inc.); mistura de silano e resina (Kerr Silane, Kerr); mistura de silano e adesivo universal (Single-bond Universal, 3M Espe). Os espécimes foram montados em um dispositivo padrão (UltradentBonding Assembly) para teste de cisalhamento Bisco Shear Bond Tester), cimentados com cimento resinoso dual (RelyX UltimateTM, 3M Espe.) e foto-polimerizados por 20s. O teste foi realizado após o período de: 24 horas e 3 meses de armazenamento em água destilada à ±36 °C. Os dados foram analisados por 3-Way Anova e Teste de Tukey (α=5%). Resultado: A resistência adesiva ao cisalhamento (SBS) foi significativamente influenciada pelo tipo de tratamento da superfície, pelo tipo de agente de união utilizado e pelo armazenamento (p<0,001). Conclusão: Adequada resistência adesiva pode ser obtida com silanos tradicionais, combinados com o pré-tratamento de superfície com ácido HF.


Subject(s)
Silanes , Ceramics , Cementation , Dentin-Bonding Agents
6.
Rev. odontol. UNESP (Online) ; 49: e20200001, 2020. tab
Article in English | LILACS, BBO | ID: biblio-1139423

ABSTRACT

Introduction: The resistance adhesive of a fiber post can be affected by several factors, such as the endodontic sealer and post-endodontic waiting time. Objective: The aim of this study was to evaluate the effect of different endodontic sealers and two different post-endodontic waiting times on the bond strength of fiber posts. Material and method: Seventy-two bovine teeth were endodontically treated and filled using three endodontic sealers: eugenol-based, epoxy resin-based, or mineral trioxide aggregate-based. The specimens were stored at 37°C for 24 hours or for 30 months. After the respective storage times, the root canals were prepared for luting fiber posts using RelyX U200. Push-out tests and analysis of failures were performed. The push-out data were analyzed by two-way analysis of variance to compare the effects of the endodontic sealer and with the t-test to compare the effects of post-endodontic waiting time. Result: The AH Plus sealer yielded the highest bond strength values at 30 months post-endodontics (11.26 Mpa) (p < 0.05), however no had difference with Endofill sealer at the same time. Endofill and MTA Fillapex sealers did not differ significantly in their effects, irrespective of the post-endodontic waiting time. Conclusion: In conclusion, the endodontic sealer used and post-endodontic waiting time affect the adhesive resistance of fiber posts. The adhesion increases significantly when the fiber post is cemented 30 months after the root canal filling, while the adhesion is reduced when cementing immediately after root canal treatment, in particular for eugenol-based endodontic sealers.


Introdução: A resistência de união de um pino de fibra pode ser afetada por vários fatores, como o cimento endodôntico e o tempo de espera pós-endodontia. Objetivo: Avaliar o efeito de diferentes cimentos endodônticos e dois tempos de espera pós-endodontia na resistência de união de pinos de fibra. Material e método: Setenta e dois dentes bovinos foram tratados endodonticamente e obturados usando três cimentos endodônticos: à base de eugenol, à base de resina epóxia ou à base de mineral trióxido agregado. Os espécimes foram armazenados a 37 ° C por 24 horas ou por 30 meses. Após, os canais radiculares foram preparados para cimentação dos pinos de fibra usando o RelyX U200. Foram realizados testes de push-out e análise de falhas. Os dados foram analisados por análise de variância bidirecional e com o teste t. Resultado: O cimento AH Plus obteve os maiores valores de resistência de união aos 30 meses pós-endodontia (11,26 Mpa) (p <0,05), no entanto, não houve diferença com o cimento Endofill no mesmo tempo. Os cimentos Endofill e MTA Fillapex não diferiram significativamente em seus efeitos, independentemente do tempo de espera pós-endodontia. Conclusão: O cimento endodôntico utilizado e o tempo de espera pós-endodontia afetam a resistência adesiva dos pinos de fibra. A adesão aumenta significativamente quando o pino de fibra é cimentado 30 meses após a obturação do canal radicular, enquanto a adesão é reduzida ao cimentar imediatamente após o tratamento do canal radicular, principalmente para cimentos endodônticos à base de eugenol.


Subject(s)
Cattle , Root Canal Obturation , Root Canal Therapy , Eugenol , Dental Cements , Dental Pins , Epoxy Resins , Analysis of Variance
7.
Rev. odontol. UNESP (Online) ; 48: e20190083, 2019. tab, graf
Article in English | LILACS, BBO | ID: biblio-1043176

ABSTRACT

Abstract Introduction Modern dentistry is reflected in the insertion of new materials with different adhesion forms in dental structures, such as the Universal adhesive system. Objective To evaluate the bond strength of the universal dentin adhesive system, in the form of self-etching and conventional application, compared with a simplified conventional adhesive system, in two distinct periods: 1 week and 6 months. Material and method 48 bovine incisors separated into 6 groups, stored for 7 days, were selected. Worn out the buccal enamel until dentin exposure. Adper Single Bond 2 (3M Espe) or SingleBond Universal (3M Espe) adhesives were applied, and catheters filled with Opallis Flow (FGM) composite were placed. After photoactivation, the catheters were removed and the specimens (n ​​= 48), stored in distilled water at 37 °C for one week and six months, were exposed. The specimens were fixed to a universal testing machine (EMIC DL 2000) with a speed of 0.5 mm / min. Bond strength (BS) was calculated in MPa, and data were statistically analyzed by Anova and Tukey test at 5% significance level. Result For Adper Single bond, the BS was equivalent in the times tested; for Universal conventional and self-conditioning time influenced the BS, with a decrease in the results. At 1 week, all stickers were different from each other, with higher BS for Universal conventional mode, followed by universal self-etching mode and then Adper Single bond. Conclusion The best results were achieved with universal adhesive in conventional mode for both tested times.


Resumo Introdução A odontologia moderna é refletida na inserção de novos materiais com diferentes formas de adesão nas estruturas dentárias, como o sistema adesivo Universal. Objetivo Avaliar a resistência adesiva do sistema adesivo universal em dentina, na forma de aplicação auto condicionante e convencional, comparando com um sistema adesivo convencional simplificado, em dois períodos distintos: 1 semana e 6 meses. Material e método Foram selecionados 48 incisivos bovinos separados em 6 grupos, armazenados por 7 dias. Desgastado o esmalte vestibular, até exposição da dentina. Aplicaram-se os adesivos Adper Single Bond 2 (3M Espe) ou SingleBond Universal (3M Espe), e sobre este, posicionados cateteres preenchidos com o compósito Opallis Flow (FGM). Após fotoativação, removeram-se os cateteres e expuseram-se os corpos de prova (n=48), armazenados em água destilada a 37 °C por uma semana e seis meses. Os corpos de prova foram fixados uma máquina universal de ensaios (EMIC DL 2000), com velocidade de 0,5 mm/min. A resistência de união (RU) foi calculada em MPa, e os dados foram analisados estatisticamente pela Anova e pelo teste de Tukey ao nível de 5% de significância. Resultado Para Adper Single bond, a RU foi equivalente nos tempos testados; para Universal modo convencional e autocondicionante o tempo influenciou na RU, havendo um decréscimo nos resultados. Em 1 semana, todos os adesivos foram diferentes entre si, com maior RU para Universal modo convencional, seguido por universal modo autocondicionante e então pelo Adper Single bond. Conclusão O melhor desempenho foi do adesivo universal na forma convencional nos dois tempos testados.


Subject(s)
Dental Cements , Dental Materials , Methods , Shear Strength , Dentin
8.
Dental press j. orthod. (Impr.) ; 23(4): 43.e1-43.e7, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-953039

ABSTRACT

ABSTRACT Introduction: It is recently suggested that titanium dioxide (TiO2) nanoparticles can be added to bracket luting agents in order to reduce bacterial activity and protect the enamel. However, it is not known if this addition can affect the shear bond strength (SBS) below clinically acceptable levels. Therefore, this study examined this matter within a comprehensive setup. Methods: This in vitro experimental study was conducted on 120 extracted human premolars randomly divided into four groups (n=30): in groups 1 and 2, Transbond XT light-cured composite with or without TiO2 was applied on bracket base; in groups 3 and 4, Resilience light-cured composite with or without TiO2 was used. Brackets were bonded to teeth. Specimens in each group (n=30) were divided into three subgroups of 10 each; then incubated at 37°C for one day, one month, or three months. The SBS and adhesive remnant index (ARI) were calculated and compared statistically within groups. Results: The SBS was not significantly different at one day, one month or three months (p>0.05) but composites without TiO2 had a significantly higher mean SBS than composites containing TiO2 (p<0.001). The SBS of Transbond XT was significantly higher than that of Resilience (p<0.001). No significant differences were noted in ARI scores based on the type of composite or addition of TiO2 (p>0.05). Conclusions: Addition of TiO2 nanoparticles to Transbond XT decreased its SBS to the level of SBS of Resilience without TiO2; thus, TiO2 nanoparticles may be added to Transbond XT composite for use in the clinical setting.


RESUMO Introdução: recentemente, sugeriu-se que nanopartículas de dióxido de titânio (TiO2) poderiam ser adicionadas ao cimento adesivo para reduzir a atividade bacteriana e proteger o esmalte. Entretanto, não se sabe se esse acréscimo pode reduzir a resistência adesiva ao cisalhamento (RAC) a níveis inferiores aos clinicamente aceitáveis. Assim, o presente estudo examinou essa questão dentro de um contexto abrangente. Métodos: esse estudo experimental in vitro foi realizado em 120 pré-molares humanos, aleatoriamente divididos em quatro grupos (n=30). Nos grupos 1 e 2, o adesivo fotopolimerizável Transbond XT com e sem TiO2 foi aplicado na base do braquete. Nos grupos 3 e 4, utilizou-se o adesivo fotopolimerizável Resilience com e sem TiO2. Os braquetes foram colados aos dentes e as amostras de cada grupo (n=30) foram divididas em três subgrupos de dez amostras cada, as quais foram incubadas a 37°C por, respectivamente, um dia, um mês e três meses. A RAC e o índice de adesivo remanescente (IAR) foram calculados e estatisticamente comparados entre os grupos. Resultados: a RAC não apresentou diferença significativa após um dia, um mês ou três meses (p > 0,05), mas os adesivos sem TiO2 apresentaram uma RAC média significativamente mais elevada do que os adesivos que continham TiO2 (p< 0,001). A RAC do Transbond XT foi significativamente mais elevada do que a do Resilience (p< 0,001). Não foram observadas diferenças significativas nos IARs, seja para o tipo de adesivo ou para a adição de TiO2 (p> 0,05). Conclusões: a adição de nanopartículas de TiO2 ao Transbond XT reduziu sua RAC a níveis semelhantes aos da RAC do Resilience TiO2. Assim, as nanopartículas de TiO2 podem ser acrescentadas ao adesivo Transbond XT para a aplicação clínica.


Subject(s)
Humans , Titanium/pharmacology , Orthodontic Brackets , Dental Enamel , In Vitro Techniques , Adhesiveness , Dental Bonding , Shear Strength , Nanoparticles
9.
Bauru; s.n; 2017. 97 p. tab, graf, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880081

ABSTRACT

Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos.(AU)


The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.(AU)


Subject(s)
Humans , Bisphenol A-Glycidyl Methacrylate/chemistry , Dental Bonding/methods , Dental Cements/chemistry , Dentin/drug effects , Saliva/chemistry , Analysis of Variance , Dentin/chemistry , Materials Testing , Microscopy, Confocal , Polymerization , Reproducibility of Results , Spectroscopy, Fourier Transform Infrared , Surface Properties , Tensile Strength , Time Factors
10.
São José dos Campos; s.n; 2015. 142 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867624

ABSTRACT

O objetivo desse estudo foi avaliar o efeito da adição de EGCG em adesivo experimental na manutenção da camada híbrida, avaliando suas propriedades mecânicas, físico-químicas e biológica. A primeira etapa do estudo envolveu a manipulação do adesivo com incorporação de EGCG (0,5%, 1,0% e 1,5%) na relação BisGMA 55% / HEMA 45%, canforoquinona 0,5% e DMAEMA 0,5%. O grau de conversão (GC) dos monômeros foi avaliado por Espectroscopia micro-Raman (GC : EGCG 1.5 - 99,11a; EGCG 1.0 - 99,02a; EGCG 0.5 - 96,58ab; Controle - 85,47b). A segunda etapa envolveu a realização de análises mecânicas e físico-químicas [resistência flexural (RF) e módulo de elasticidade (ME); módulo de resiliência (RE) e resistência a compressão(RCo); sorção (A) e solubilidade (S) em água; contração de polimerização (CP)]; teste de resistência à microtração (RA) imediato (24 h) e longitudinal (6 meses); e teste biológico [ensaio de citotoxicidade (CI)]. Os resultados foram: RF, ME, RE, RCo e CP não apresentaram diferença significativa entre os grupos. Os testes de A e S apresentaram redução dos valores para os grupos EGCG 0.5 e 1.0; RA imediato (24 h) não apresentou diferença entre os grupos. Após 6 meses houve redução dos valores somente para os grupos Controle e EGCG 1.5, os grupos EGCG 0.5 e 1.0 mantiveram os valores de RA constantes. CI: a incorporação de EGCG aumentou a viabilidade celular nas diluições de 0,1% e 1,0%, comparado ao grupo Controle. Pôde-se concluir que a incorporação de EGCG independente da concentração não afetou o GC. As concentrações de 0,5% (100 μg/ml) e 1,0% (200 μg/ml) em volume de EGCG é capaz de preservar a camada híbrida formada e prorrogar a longevidade das restaurações em resina composta, além de aumentar a viabilidade celular


The aim of this study was to evaluate the effect of EGCG in an experimental adhesive to reduce the hybrid layer degradation, through mechanical, physical-chemical and biological analysis. The first step of this study involved manipulation of the adhesive model with the incorporation three different concentrations of EGCG (0.5%, 1.0% and 1.5%) in relation BisGMA 55% / 45% HEMA, 0.5% camphorquinone and 0.5% DMAEMA. The conversion degree (DC) of adhesive monomers was evaluated by micro-Raman spectroscopy (GC: EGCG 1.5 (1.5%) - 99,11a; EGCG 1.0 (1.0%) - 99,02a; EGCG 0.5 (0.5%) - 96,58ab; Control - 85,47b). The second step involved the mechanical and physicochemical analysis [flexural strength (FS) and elastic modulus (EM); resiliency modulus (RM) and compressive bond strength (CBS), sorption (A) and solubility (S) in water; shrinkage polymerization (SP)]; microtensile bond strength test (μTBS) immediately (24 h) and longitudinal (6 months) and biological analyze [cytotoxicity assay (CY)]. The results were: FS, EM, RM, CBS and SP showed no significant difference between groups; A and S tests showed reduced values only for EGCG 0.5 and 1.0 groups. RA immediately (24) did not differ between groups. After six months there was a reduction of the values only for the control and EGCG 1.5 groups, EGCG groups 0.5 and 1.0 maintained the RA values. CY: EGCG incorporation increased the cell viability in 0.1% and 1.0% dilutions compared to the control group. It was concluded incorporation of EGCG at 0.5, 1.0 and 1.5 concentrations did not affect the degree of conversion of the monomers. Thus, the incorporation of 0.5% (100 μg/ml) and 1.0% (200 μg/ml) EGCG amount can preserve the hybrid layer formed and prolong longevity composite resin restorations in addition to increasing cell viability


Subject(s)
Adhesives , Dentin
11.
Braz. dent. sci ; 18(4): 19-24, 2015. tab
Article in English | LILACS | ID: lil-786316

ABSTRACT

The aim of the present study was to compare the effects of Nd:YAG laser application in root canals on bond strengths of fiber posts.Material and Methods: Thirty single-rooted bovines were randomly divided into three groups (n = 10); root canal instrumentation was performed, and pretreatment was conducted as follows: C group: conventional treatment (without laser irradiation); ALC group: Nd:YAG laser was applied after adhesive; and LAC group: Nd:YAG laser was applied before adhesive. The fiber posts Rebilda 15 DC (Voco) were cemented with an adhesive system and resin cement,in accordance with the manufacturer’s instructions. Six slices with 1.0mm height was obtained for ofeach root and bond strength was measured by pushout test using a universal testing machine (0.5 mm/min). Data were analyzed using Kruskal-Wallis and Dunn’s tests (p < 0.05). Results: Push-out bond strengths to root canal dentin were affected by the type of treatment and root third. The use of Nd: YAGlaser after the application of adhesive system had ahigher bonding performance compared with the useof laser before the application. However, both of them were similar to the control group. Also, cervical and medium third presented higher bond strength values than the apical third. Conclusion: It must be conclude, in the conditions in which the studywas conduct, that the use of laser irradiation didnot improve the bonding performance of resinous cement inside the root canal...


Objective: O objetivo deste estudo foi comparar o efeito da aplicação intrarradicular do laser Nd:YAG na adesão de pinos de fibra de vidro. Material e Métodos: Trinta raízes unirradiculares de incisivos bovinos foram selecionadas, e após instrumentação, foram divididas aleatoriamente em três grupos (n= 10) de acordo com o tratamento das paredes do canal: C: tratamento convencional (sem radiação laser), ALC: aplicação do Laser Nd:YAG após o adesivo; e LAC: aplicação do laser antes do adesivo. Pinos de fibra de vidro Rebilda 15 DC (Voco) foram cimentados com adesivo e cimento resinoso de acordo com instruções do fabricante. Seis fatias (duas para cada terço radicular) com 1 mm de espessura foram obtidas de cada raiz para mensuração da resistência adesiva por meio de teste push-out realizado em máquina de ensaio universal (0,5 mm/min). Os dados foram analisados por meio dos testes Kruskal-Wallis e Dunn (p < 0,05). Resultados: A resistência adesiva dos pinos na dentina radicular foi influenciada pelo tipo de tratamento e terço radicular. O uso do laser de Nd:YAG após a aplicação do adesivo apresentou melhor performance comparada ao seu uso antes do adesivo, porém, ambos foram similares ao controle. Ainda, os terços cervical e médio apresentaram maior resistência comparado ao apical. Conclusão: Conclui-se que, ouso da irradiação laser nos parâmetros estudados, não melhora a performance adesiva de cimentos resinosos dentro do canal radicular...


Subject(s)
Animals , Cattle , Dental Pins , Lasers, Solid-State , Root Canal Filling Materials
12.
São José dos Campos; s.n; 2015. 142 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-870203

ABSTRACT

O objetivo desse estudo foi avaliar o efeito da adição de EGCG em adesivo experimental na manutenção da camada híbrida, avaliando suas propriedades mecânicas, físico-químicas e biológica. A primeira etapa do estudo envolveu a manipulação do adesivo com incorporação de EGCG (0,5%, 1,0% e 1,5%) na relação BisGMA 55% / HEMA 45%, canforoquinona 0,5% e DMAEMA 0,5%. O grau de conversão (GC) dos monômeros foi avaliado por Espectroscopia micro-Raman (GC : EGCG 1.5 - 99,11a; EGCG 1.0 - 99,02a; EGCG 0.5 - 96,58ab; Controle - 85,47b). A segunda etapa envolveu a realização de análises mecânicas e físico-químicas [resistência flexural (RF) e módulo de elasticidade (ME); módulo de resiliência (RE) e resistência a compressão(RCo); sorção (A) e solubilidade (S) em água; contração de polimerização (CP)]; teste de resistência à microtração (RA) imediato (24 h) e longitudinal (6 meses); e teste biológico [ensaio de citotoxicidade (CI)]. Os resultados foram: RF, ME, RE, RCo e CP não apresentaram diferença significativa entre os grupos. Os testes de A e S apresentaram redução dos valores para os grupos EGCG 0.5 e 1.0; RA imediato (24 h) não apresentou diferença entre os grupos. Após 6 meses houve redução dos valores somente para os grupos Controle e EGCG 1.5, os grupos EGCG 0.5 e 1.0 mantiveram os valores de RA constantes. CI: a incorporação de EGCG aumentou a viabilidade celular nas diluições de 0,1% e 1,0%, comparado ao grupo Controle. Pôde-se concluir que a incorporação de EGCG independente da concentração não afetou o GC. As concentrações de 0,5% (100 μg/ml) e 1,0% (200 μg/ml) em volume de EGCG é capaz de preservar a camada híbrida formada e prorrogar a longevidade das restaurações em resina composta, além de aumentar a viabilidade celular.


The aim of this study was to evaluate the effect of EGCG in an experimental adhesive to reduce the hybrid layer degradation, through mechanical, physical-chemical and biological analysis. The first step of this study involved manipulation of the adhesive model with the incorporation three different concentrations of EGCG (0.5%, 1.0% and 1.5%) in relation BisGMA 55% / 45% HEMA, 0.5% camphorquinone and 0.5% DMAEMA. The conversion degree (DC) of adhesive monomers was evaluated by micro-Raman spectroscopy (GC: EGCG 1.5 (1.5%) - 99,11a; EGCG 1.0 (1.0%) - 99,02a; EGCG 0.5 (0.5%) - 96,58ab; Control - 85,47b). The second step involved the mechanical and physicochemical analysis [flexural strength (FS) and elastic modulus (EM); resiliency modulus (RM) and compressive bond strength (CBS), sorption (A) and solubility (S) in water; shrinkage polymerization (SP)]; microtensile bond strength test (μTBS) immediately (24 h) and longitudinal (6 months) and biological analyze [cytotoxicity assay (CY)]. The results were: FS, EM, RM, CBS and SP showed no significant difference between groups; A and S tests showed reduced values only for EGCG 0.5 and 1.0 groups. RA immediately (24) did not differ between groups. After six months there was a reduction of the values only for the control and EGCG 1.5 groups, EGCG groups 0.5 and 1.0 maintained the RA values. CY: EGCG incorporation increased the cell viability in 0.1% and 1.0% dilutions compared to the control group. It was concluded incorporation of EGCG at 0.5, 1.0 and 1.5 concentrations did not affect the degree of conversion of the monomers. Thus, the incorporation of 0.5% (100 μg/ml) and 1.0% (200 μg/ml) EGCG amount can preserve the hybrid layer formed and prolong longevity composite resin restorations in addition to increasing cell viability.


Subject(s)
Adhesives , Dentin
13.
Braz. dent. sci ; 18(2): 31-37, 2015. tab
Article in English | LILACS, BBO | ID: lil-766808

ABSTRACT

Objetivo: Apesar da resina composta e o cimento de ionômero de vidro serem amplamente usados para restaurações cervicais, sob condições erosivas estas podem desgastar mais rapidamente. Este estudo objetivou comparar a resistência adesiva ao microcisalhamento de uma resistência de união (RC) e um cimento de ionômero de vidro modificado por resina (RMGIC) à dentina erodida associada à Clorexidina 2% num período de até 6 meses. Material e Métodos: Oitenta terceiros molares humanos foram cortados e uma dentina regular foi obtida, e subsequentemente, foram inclusos com resina acrílica em tubos de PVC. Os dentes foram divididos em dois grupos, de acordo com o tratamento recebido: Adper Single Bond 2 + RC Filtek Z250 (Z) ou RMGIC Vitremer (V). Metade dos corpos de prova foram imersos em saliva artificial (AS) por 24 h (grupo controle) e metade foi erodido artificialmente 3x/1 min diariamente com Coca Cola ®-RC por 5 dias. Metade dos corpos de prova, para cada condição descrita, recebeu água e outra metade a clorexidina 2% por 1 min, antes da restauração. Para todos os grupos, os corpos de prova foram armazenados em saliva artificial renovada semanalmente até os testes. A resistência de união ao microcisalhamento foi avaliado após 1 e 6 meses. Os resultados foram analisados com teste ANOVA 4 critérios e Tukey (p < 0,05). Resultados: Os fatores materiais, substrato e tempo foram estatisticamente significantes, além da interação entre o material e o tempo. O tratamento (água X clorexidina) não foi um fator significante. As restaurações com Z demonstraram resistência de união significantemente maior comparada ao V, em todas as situações. Conclusão: Tanto para a dentina sadia quanto erodida, a resina composta apresentou maior resistência de união comparada ao cimento de ionômero de vidro. O tempo e uso da clorexidina não interferiu na resistência de união. A resina composta demonstrou maior resistência adesiva quando comparada ao cimento de ionomero de vidro.


Objective: Although resin composites and glassionomer cements are widely used for dental cervical region restorations, under erosive condition they can wear out quickly. This study aimed to compare, by means of microshear bond strength, the performance of a resin composite (RC) and a resin-modified glassionomer cement (RMGIC) to eroded dentin and its association with 2% chlorhexidine (CHX) up to 6 months. Material and Methods: Eighty sound third molars teeth were cut to obtain flat coronal dentin, which were subsequently embedded in self-curing acrylic resin circular molds. Teeth were divided into two groups, according to the treatment with the Adper Single Bond 2 + RC Filtek Z250 (Z) or the RMGIC Vitremer (V). Half of the specimens were immersed in artificial saliva-AS (control groups) and half subjected to 3x/1 min daily immersion in Regular Coca Cola ®-RC for 5 days. Half of the specimens for each described condition were treated with water and half with 2% chlorhexidine for 1 min prior the restoration. For all groups, the specimens were stored in artificial saliva weekly renewed up to tests. The microshear bond strength was evaluated after 1 month and 6 months. Data, in normal distribution, were analyzed with four-way ANOVA and Tukey (p < 0.05). Results: The factors materials, substrate and time were statistically significant and also the interaction between material and time. Treatment (water x CHX) was not a significant factor. Restorations with Z showed significantly higher bond strength compared to V in all situations. There was a reduction in bond strength values over time for all tested conditions. Conclusion: For both sound and eroded dentin, the resin composite presented higher bond strength compared to resin-modified glassionomer material. The bond strength performance was overall reduced with time and the use of chlorexidine itself did not interfere on bond strength through time...


Subject(s)
Humans , Chlorhexidine , Dentin , Glass Ionomer Cements , Resins, Synthetic , Tooth Erosion
14.
Braz. dent. sci ; 18(3): 98-106, 2015. ilus, tab
Article in English | LILACS, BBO | ID: lil-772993

ABSTRACT

Muitos sistemas adesivos foram desenvolvidos na última década. O objetivo desse estudo foi avaliara resistência adesiva ao cisalhamaneto (RAC)de bráquetes ortodônticos aderidos com primer convencional (PC) ou primer auto-condicionante (PAC), submetidos à ciclagem térmica (CT) e ciclagem térmico-mecânica (CTM). Incisivos bovinos (n =90)foram randomicamente divididos em 2 grupos (n =45) para a colagem dos bráquetes: XT (Transbond XT, 3M-Unitek, CA, USA); SEP (Transbond Plus SEP,3M-Unitek, CA, USA). Após o procedimento adesivo os grupos forma subdivididos em 3 sub-grupos: SC(sem ciclagem) – 1 e 4 (n =15 cada); CTM (ciclagem térmico-mecânica)- 2 e 5 (n = 15 cada); CT (ciclagem térmica)- 3 e 6 (n = 15 cada). Um simulador de fadiga térmica foi usado para os subgrupos 3 e 6, que fioram submetidos a 500 ciclos térmicos entre 5 and 55 C (ISO 11405). Os subgrupos 2 e 5 foram submetidos à ciclagem térmico-mecânica em um simulador de fadiga. Os espécimes foram colocados em uma basede metal num ângulo de 45 e os braquetes receberam impulsos de 1 bar e 4 Hz de frequência, por uma agulha de metal de 2.5 mm de diâmetro fixada na haste superior do equipamento. Foram submetidos a 100.000 ciclos mecânicos e 500 ciclos térmicos entre 5 and 55 C. O teste de RAC foi realizado emuma máquina universal de testes (1mm/min). Após orompimento da união foi realizada uma avaliação emmicroscopia óptica para avaliar a penetração adesivae o Índice de Permanência do Adesivo (IPA) sobreo esmalte. Os resultados mostraram maiores valores de RAC (14,70 ± 4,85 MPa) para o SEP. A CT não influenciou os resultados para o XT (NC- 11,44 MPa;TC - 11,20 MPa; TMC - 11,19 MPa), enquanto para oSEP, a CTM mostrou maiores valores (16,84 MPa)...


Several adhesive systems have been developed in the last decade. The aim of the current studywas to evaluate the shear bond strength (SBS) of orthodontic brackets bonded with conventional primers (XT) or self-etching primers (SEP), by means of thermocycling (TC) and thermomechanical(TM) procedures. 90 bovine incisors were randomly divided into 2 groups (45 specimens each) for brackets bonding: XT (Transbond XT, 3M-Unitek,CA, USA); SEP (Transbond Plus SEP, 3M-Unitek,CA, USA). After bonding, groups were divided into 3subgroups: NC (no cycling)- 1 and 4 (n = 15 each),TMC – 2 and 5 (n =15 each); and TC- 3 and 6 (n=15 each). The fatigue simulator was used for thethermal fatigue test of groups 3 and 6, which were submitted to thermal variation cycles - 500 cyles were carried out in between 5 and 55 C ( ISO 11405). Groups 2 and 5 were submitted to thermomechanicaltests by using the mechanical fatigue simulator. Thespecimens were placed at a metal base at an angleof 45, in a way that the 2.5 mm diameter metalneedle was fixed in the upper part of the cyclingmachine and could induce impulses of 1 bar loadintensity and 4 Hz frequency (4 cycles per second)on the bracket. The samples were submitted to 100000 mechanical cycles and 500 thermal cycles which varied from 5C to 55C. The SBS test was performed in a universal testing machine (1 mm/min). Afterdebonding, optic microscopic evaluation for adhesive penetration and Adhesive Remaining Index (ARI)analyses in the enamel surface were performed.The results showed higher SBS (14.70 ± 4.85 MPa)values for SEP. The SBS remained similar despitecycling (NC-11.44 MPa; TC-11.20 MPa; TMC-11.19MPa) for XT, meanwhile for SEP, ...


Subject(s)
Cattle , Orthodontic Brackets , Shear Strength , Materials Testing
15.
São José dos Campos; s.n; 2014. 142 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867618

ABSTRACT

O objetivo deste estudo foi empregar diferentes abordagens estatísticas emdados obtidos em ensaios de micro e macrotração, em dois períodos detempo de armazenamento, a fim de descrever e quantificar a variabilidadecomumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmaltee as faces vestibulares foram desgastadas expondo superfície dedentina plana. Os dentes foram embutidos em resina acrílica ealeatoriamente designados a quatro grupos (n = 12) para avaliação daresistência de união (RU). Para o teste de microtração foi aplicado o adesivoAdper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguidode jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foiobtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmos resultados, ou seja, a existência do efeito envelhecimento, apenas, para a microtração; na comparação entre macro e microtração ...


The aim of this study was to use different statistical approaches on data obtainedfrom micro and macrotensile tests in two periods of time storage, in order todescribe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibullanalysis for the data of BS (MPa) of the experimental conditions were: G1(module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%),complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison between macro and microtensile (model 2-way ANOVA), direct evaluation between tests ...


Subject(s)
Biostatistics , Statistical Distributions , Materials Testing
16.
São José dos Campos; s.n; 2014. 142 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-870207

ABSTRACT

O objetivo deste estudo foi empregar diferentes abordagens estatísticas emdados obtidos em ensaios de micro e macrotração, em dois períodos detempo de armazenamento, a fim de descrever e quantificar a variabilidadecomumente encontrada nos testes de adesão. Foram selecionados 48 dentes bovinos. As raízes seccionadas a 2 mm abaixo da junção cementoesmaltee as faces vestibulares foram desgastadas expondo superfície dedentina plana. Os dentes foram embutidos em resina acrílica ealeatoriamente designados a quatro grupos (n = 12) para avaliação daresistência de união (RU). Para o teste de microtração foi aplicado o adesivoAdper Single Bond 2- (SE Bond 2- 3M-ESPE) numa área de 8 mm2, seguidode jato de ar por 2 a 5 s e fotopolimerização por 15 s e, a seguir, inserida a resina composta Z350 XT- (3 M-ESPE). Após 24 h de armazenamento, em água destilada a 37 ºC, para cada dente um número variável de palitos foiobtido. Doze dentes foram submetidos ao teste de microtração após 24 h (G1) e outros 12 submetidos à termociclagem (G2) seguido de microtração. Para a macrotração, a base menor dos espécimes cônicos foi de 2 mm. Doze amostras após 24 h foram submetidas ao teste de macrotração (G3) e as outras doze, após as 24 h, termocicladas (G4). Os dados foram submetidos a uma análise exploratória; seguidos de uma análise confirmatória (inferencial). A estatística descritiva e o resultado da análise de Weibull para os dados de RU (MPa) foram: G1(módulo; média ± desvio padrão: 2,54; 10,76 ± 4,21); G2 (3,36; 19,34 ± 6,42); G3 (1,96; 3,17 ± 1,51; G4 (1,75; 2,86 ± 1,68). O teste ANOVA (2-way), α = 5%, indica efeito interação significante e, os testes de Tukey e de Dunn (5%), complementaram os resultados. Pôde-se concluir: as diferentes estratégias estatísticas (análise de Weibull, análise exploratória e abordagem paramétrica) indicaram os mesmos resultados, ou seja, a existência do efeito envelhecimento, apenas, para a microtração; na comparação entre macro e microtração...


The aim of this study was to use different statistical approaches on data obtainedfrom micro and macrotensile tests in two periods of time storage, in order todescribe and quantify the variability commonly found in adhesion tests. 48 bovine teeth were selected. The roots were sectioned 2 mm below the cement-enamel junction and the buccal surfaces were ground to exposure a dentin flat surface. The teeth were embedded in acrylic resin and randomly assigned to four groups (n = 12) to evaluate the bond strength (BS). For the microtensile test the adhesive Adper Single Bond 2 - (2 SE Bond - 3M - ESPE) was applied in an area of 8 mm2, followed by air jet during 2 to 5 s and curing for 15 s. Right after the XT - Z350 composite resin (3M ESPE) was inserted. After 24 h of storage in distilled water at 37 °C, for each tooth a variable number of sticks was obtained. Twelve teeth were submitted to microtensile test after 24 h (G1) and other 12 to thermocycling (G2) and microtensile test. For macrotensile, the smallest base of conical shape specimens was 2 mm. After 24 h twelve samples were subjected to macrontesile test (G3) and the other twelve, after 24 h, were thermocycled (G4). The data were submitted to an exploratory analysis, followed by a (inferential) confirmatory analysis. Descriptive statistics and the results of Weibullanalysis for the data of BS (MPa) of the experimental conditions were: G1(module; mean ± standard deviation: 2.54; 10.76 ± 4.21); G2 (3.36; 19.34 ± 6.42); G3 1.96; 3.17 ± 1.51; G4 (1.75; 2.86 ± 1.68). The ANOVA (2-way), α = 5%, indicated significant interaction effect, and Tukey tests and Dunn (5%),complemented the results. The conclusion is: the different statistics strategies (Weibull analysis, exploratory analysis and parametric approach) showed the same results, namely the existence of the aging effect only for the microtensile bond; in the comparison between macro and microtensile (model 2-way ANOVA), direct evaluation between tests...


Subject(s)
Biostatistics , Statistical Distributions , Materials Testing
17.
São José dos Campos; s.n; 2013. 127 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867550

ABSTRACT

Objetivou-se avaliar o efeito de métodos de envelhecimento na resistência adesiva ( σ) de três sistemas de cimentação resinosa de ativação dual (RXA- RelyX ARC, RXU- RelyX U100 e PF- PanaviaF) entre a dentina e uma cerâmica à base de zircônia estabilizada poróxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície dentinária oclusal de 72 molares humanos hígidos foi exposta e condicionada conforme as instruções dos fabricantes. Os blocos cerâmicos (72) foram cortados,planificados, sinterizados e divididos em dois grupos conforme o tipo de tratamento de superfície: PA- jateamento com óxido de alumínio (≤45μm) ou SC- silicatização (Rocatec Soft, 3M ESPE). A cimentação dos blocos cerâmicos foi realizada de acordo com as instruções dos fabricantes, constituindo 6 grupos que foram armazenados em água destilada à 37°C por 24 h. Os conjuntos dente-cimento resinoso cerâmica foram cortados no sentido x e y, produzindo,aproximadamente, 9 corpos de prova (cp) em forma de barra (área adesiva de 0,9 ± 0,1 mm2) por conjunto. Os cp de cada grupo foram divididos aleatoriamente em 4 condições de envelhecimento:armazenagem em água destilada (A) a 37oC por 120 ou 180 dias (d); etermociclagem com 30.000x ou 60.000x (5ºC-55ºC); constituindo 24 grupos (n>12). O teste de micro-tração foi realizado em uma máquina de ensaio universal (1 mm/min). A σ foi calculada e os dados foram analisados estatisticamente através da ANOVA e teste de Tukey(α=0,05). Os grupos RXA-SC 180 d e PF-PA 120 d apresentaram os mais altos valores de σ (32,9 e 29,6 MPa, respectivamente). Os grupos RXA-PA 30.000x (8,9 MPa) e RXU-SC 180 d (8,1 MPa) mostraram os valores mais baixos de σ. O envelhecimento por TC não prejudicou qualquer dos grupos experimentais, mas o envelhecimento por A reduziu significativamente os valores de σ nos grupos RXU-SC e PF-PA


The aim of this study was to evaluate the bond strength (σ) of resincement systems (RXA- RelyX ARC; RXU- RelyX U100; and PFPanaviaF) to dentin and yttria-stabilized zirconia-based ceramic (YZIn-Ceram YZ) after different surface treatments and aging. The occlusal dentin of 72 sound human molars was exposed and conditioned according to the manufacturers’ instructions. Ceramic blocks (72) were cut, flattened, sintered, and divided into two groups according to the type of surface treatment: PA- airborne particle abrasion (≤ 45μm alumina particles), and SC- tribochemical silica coating (Rocatec Soft, 3M ESPE). The cementation procedure followed the instructions of each manufacturer, resulting in 6 groups of tooth-cement-ceramic blocks that were stored in 37°C distilled water for 24 h before cutting into nontrimmed bar-shaped specimens (A- adhesive area= 0.9 ± 0.1 mm²).Approximately 9 specimens per block were obtained and they were randomly assigned to one of the 4 aging conditions: 120 or 180 days stored in 37oC distilled water; and thermocycling (5ºC-55ºC) with 30,000 or 60,000 cycles. The experimental design resulted in 24 groups (n>12).The specimens were loaded in tension (F) until failure using a universal testing machine (crosshead speed: 1 mm/min). The σ (F/A) was calculated and data was statistically analyzed using ANOVA and Tukey tests (α=0.05). Groups RXA-SC 180 d and PF-PA 120 d showed the highest σ values (32.9 and 29.6 MPa, respectively). Groups RXA-PA30,000x (8.9 MPa) and RXU-SC 180 d (8.1 MPa) presented the lowest σ values. Thermocycling did not reduce the σ values of any experimental group, but water storage decreased the σ values for RXU-SC and PF-PA groups


Subject(s)
Ceramics , Dental Cements , Tensile Strength , Dentin
18.
São José dos Campos; s.n; 2013. 139 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867567

ABSTRACT

O objetivo deste estudo foi avaliar a influencia da Clorexidina, Ácido Hialurônico e Vitamina C na resistência adesiva à dentina e na propriedade mecânica (nanodureza e módulo de elasticidade) da camada híbrida. A dentina superficial de noventa e seis dentes bovinos foi exposta. Os espécimes foram divididos em quatro grupos (n=24) de acordo com o tratamento dentinário: G1 (Controle) - aplicação do sistema adesivo (Adper Single Bond 2); G2 - tratamento com solução de clorexidina a 2% por 1min + sistema adesivo; G3 - tratamento de solução com Ácido Hialurônico1% por 1 min + sistema adesivo; G4 - tratamento com solução de VitaminaC (Vit C) 10% por 1 min + sistema adesivo. Após polimerização do sistema adesivo foi aplicado duas camadas de resina composta Filtek 250 (3M ESPE) de forma incremental com auxílio de uma matriz e fotopolimerizada por 20 s cada. Em seguida, os espécimes foram armazenados em água destilada a 37°C por 24 h (n=12) e 6 meses (n=12). Após o período de armazenamento, os espécimes foram seccionados onde se obteve um espécime de aproximadamente 1 mm2 de área. Foram submetidos ao testede microtração em máquina de ensaio universal (DL-1000, EMIC/10kgf/ 0,5 mm/min). Cinco espécime de cada grupo armazenado por 6 meses foi submetido ao teste de nanodureza e módulo de elasticidade da camada híbrida. Os dados foram submetidos aos testes estatísticos Anova 2 fatores e Tukey. No grupo após armazenamento 24 h mostraram que os maiores valores foram obtidos nos G1, G2 e G3, mas após 6 meses de armazenamento apenas o G2 e G3 apresentaram os maiores valores. Com relação às propriedades mecânicas o G3 apresentou o maior valor de dureza quando comparado aos demais grupos estudados. Não houve diferença estatística significante quanto ao módulo de elasticidade entre os grupos. Concluimos que a aplicação da clorexidina e ácido hialurônicona dentina foi eficiente em manter os valores da resistência adesiva após 6 meses de armazenamento entretato...


The aim of this study was to evaluate the influence of chlorhexidine, hyaluronicacid and C vitamin C on dentin bond strength and on the hybrid layer mechanical properties. The buccal surface of ninety six extracted bovine teeth was ground to exposure a flat dentin surface. The specimens were divided in four experimental groups (n=24): G1 (Control) - application ofthe adhesive system (Adper Single Bond 2); G2: dentin treatment with chlorhexidine 2% for 1 min + adhesive system; G3: dentin treatment with hyaluronic acid 1% for 1 min + adhesive system; G4: dentin treatment withC vitamin 10% for 1 min + adhesive system. After polymerization of the adhesive system, two increments of the composite resin, Filtek Z 350 (3MESPE), were placed on dentin with the aid of a matrix and polymerized for20 s each. The specimens were stored in distilled water at 37ºC for 24 h(n=12) and 6 months (n=12). They were then sectioned in order to obtain specimens with an area of approximately 1 mm2. They were submitted to microtensile bond strength tests using a universal testing machine (DL- 1000, EMIC/10 kgf/ 0,5 mm/min). One specimen of each of the groups stored for 6 months was submitted to nanohardness and elasticity moduletests for the hybrid layer. Data were analyzed by two-way ANOVA andTukey's test. Tests performed after 24 h showed higher adhesive bondstrength for groups G1, G2 and G3, but after six months the highest valueswere presented by groups G2 and G3. Nanohardness tests revealed greater resistance for G3 compared to the other groups. Modulus of elasticity was found to be the same for all groups. It could be concluded that the application of chlorhexidine and hyaluronic acid on dentin was effective in keeping high bond strength values after 6 months but regarding the hybrid layer only hyaluronic acid increased nanohardness


Subject(s)
Chlorhexidine , Dentin , Hyaluronic Acid
19.
São José dos Campos; s.n; 2013. 127 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-870166

ABSTRACT

Objetivou-se avaliar o efeito de métodos de envelhecimento na resistência adesiva ( σ) de três sistemas de cimentação resinosa de ativação dual (RXA- RelyX ARC, RXU- RelyX U100 e PF- PanaviaF) entre a dentina e uma cerâmica à base de zircônia estabilizada poróxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície dentinária oclusal de 72 molares humanos hígidos foi exposta e condicionada conforme as instruções dos fabricantes. Os blocos cerâmicos (72) foram cortados,planificados, sinterizados e divididos em dois grupos conforme o tipo de tratamento de superfície: PA- jateamento com óxido de alumínio (≤45μm) ou SC- silicatização (Rocatec Soft, 3M ESPE). A cimentação dos blocos cerâmicos foi realizada de acordo com as instruções dos fabricantes, constituindo 6 grupos que foram armazenados em água destilada à 37°C por 24 h. Os conjuntos dente-cimento resinoso cerâmica foram cortados no sentido x e y, produzindo,aproximadamente, 9 corpos de prova (cp) em forma de barra (área adesiva de 0,9 ± 0,1 mm2) por conjunto. Os cp de cada grupo foram divididos aleatoriamente em 4 condições de envelhecimento:armazenagem em água destilada (A) a 37oC por 120 ou 180 dias (d); etermociclagem com 30.000x ou 60.000x (5ºC-55ºC); constituindo 24 grupos (n>12). O teste de micro-tração foi realizado em uma máquina de ensaio universal (1 mm/min). A σ foi calculada e os dados foram analisados estatisticamente através da ANOVA e teste de Tukey(α=0,05). Os grupos RXA-SC 180 d e PF-PA 120 d apresentaram os mais altos valores de σ (32,9 e 29,6 MPa, respectivamente). Os grupos RXA-PA 30.000x (8,9 MPa) e RXU-SC 180 d (8,1 MPa) mostraram os valores mais baixos de σ. O envelhecimento por TC não prejudicou qualquer dos grupos experimentais, mas o envelhecimento por A reduziu significativamente os valores de σ nos grupos RXU-SC e PF-PA.


The aim of this study was to evaluate the bond strength (σ) of resincement systems (RXA- RelyX ARC; RXU- RelyX U100; and PFPanaviaF) to dentin and yttria-stabilized zirconia-based ceramic (YZIn-Ceram YZ) after different surface treatments and aging. The occlusal dentin of 72 sound human molars was exposed and conditioned according to the manufacturers’ instructions. Ceramic blocks (72) were cut, flattened, sintered, and divided into two groups according to the type of surface treatment: PA- airborne particle abrasion (≤ 45μm alumina particles), and SC- tribochemical silica coating (Rocatec Soft, 3M ESPE). The cementation procedure followed the instructions of each manufacturer, resulting in 6 groups of tooth-cement-ceramic blocks that were stored in 37°C distilled water for 24 h before cutting into nontrimmed bar-shaped specimens (A- adhesive area= 0.9 ± 0.1 mm²).Approximately 9 specimens per block were obtained and they were randomly assigned to one of the 4 aging conditions: 120 or 180 days stored in 37oC distilled water; and thermocycling (5ºC-55ºC) with 30,000 or 60,000 cycles. The experimental design resulted in 24 groups (n>12).The specimens were loaded in tension (F) until failure using a universal testing machine (crosshead speed: 1 mm/min). The σ (F/A) was calculated and data was statistically analyzed using ANOVA and Tukey tests (α=0.05). Groups RXA-SC 180 d and PF-PA 120 d showed the highest σ values (32.9 and 29.6 MPa, respectively). Groups RXA-PA30,000x (8.9 MPa) and RXU-SC 180 d (8.1 MPa) presented the lowest σ values. Thermocycling did not reduce the σ values of any experimental group, but water storage decreased the σ values for RXU-SC and PF-PA groups.


Subject(s)
Ceramics , Dental Cements , Tensile Strength , Dentin
20.
Braz. dent. sci ; 16(3): 56-62, 2013. tab
Article in English | LILACS, BBO | ID: lil-707563

ABSTRACT

Objetivo: O objetivo deste estudo foi avaliar a resistência de união dentinária tratada com clorexidina, ácido hialurônico, vitamina C e chá verde. Material e Métodos: As raízes de 50 dentes bovinos foram removidas e a superfície de dentina vestibular exposta. Após o condicionamento ácido, os espécimes foram divididos em 5 grupos (n = 10), de acordo com as estratégias adesivas na dentina: CO - dentina não tratada; CHX – tratamento com clorexidina 2% por 30 s; HA - tratamento com ácido hialurônico 1% por 30 s; VC - tratamento com vitamina C 10% por 30 s; GT – tratamento com extrato de chá verde 1% por 30 s. Sistema adesivo Adper Single Bond II foi aplicado segundo recomendações do fabricante. Os espécimes foram restaurados com uma camada de 4 mm de espessura de resina composta, que foi polimerizada por 40 s. As amostras foram armazenadas em água destilada a 37 ° C durante 24 h, e seccionada em palitos de 1 x 1 mm2 contendo a interface adesiva. Teste de microtração foi realizado com uma máquina de ensaios universal a uma velocidade de 0,5 mm/min. Resultados: Os resultados foram analisados com teste de variância ANOVA um-fator e testes de múltipla comparação de Tukey (p < 0,05). Grupo GT apresentou os maiores valores de resistência de união (29,4 ± 3,1) a, mas sem diferença significativa em relação aos demais grupos experimentais HA (26,7 ± 3,1) ab, CHX (25,4 ± 2,6) ab e VC (22,4 ± 6,0) b. Resistência de união dos grupos experimentais não foi significativamente diferente do grupo CO. Conclusão: a resistência de união imediata foi mantida mesmo após os diferentes tratamentos dentinários.


Objective: The aim of this study was to evaluate the bond strength of dentin treated with chlorhexidine, hyaluronic acid, vitamin C and green tea. Material and Methods: The roots of 50 bovine teeth were removed and buccal coronal dentin was exposed. After acidetching, the specimens were divided into 5 groups (n= 10), according to the dentin treatment strategy: CO -untreated dentin; CHX - treated with 2 wt% chlorhexidine for 30 s; HA - treated with 1 wt% hyaluronic acid for 30s; VC - treated with 10 wt% vitamin C for 30 s; GT - treated a 1% green tea extract for 30 s. Adper Single Bond was then applied to the treated according to the manufacturer’s recommendations. The specimens were restored with a 4 mm thick layer of the resin composite, which was polymerized for 40 s. The specimens were stored in distilled water at 37°C for 24 h and sectioned into 1 x 1 mm2 sticks containing the adhesive interface. Microtensile bond strength testing was performed with a universal testing machine at a cross-head speed of 1.0 mm/min. Results: The results were analyzed with onefactor ANOVA and Tukey’s multiple comparison tests. GT group presented the highest values bond strength (29.4 ± 3.1) a, but no significant difference compared to the other experimental groups HA (26.7 ± 3.1) ab, CHX (25.4 ±2.6) ab and VC (22.4 ± 6.0) b. Bond strengths of experimental groups were not significantly different from the CO. Conclusion: Immediate bond strength was preserved after acid-etched dentin was treated.


Subject(s)
Animals , Cattle , Ascorbic Acid , Camellia sinensis , Chlorhexidine , Hyaluronic Acid
SELECTION OF CITATIONS
SEARCH DETAIL